m |
m (→Related pages) |
||
(42 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | + | [[File:Technical information page image.png|right|100px|alt=image]] | |
+ | [[File:Pdf image.png|100px|thumb|left|alt=pdf image|<font size=3>[https://stormwater.pca.state.mn.us/index.php?title=File:Soils_with_low_infiltration_capacity_-_Minnesota_Stormwater_Manual.pdf Download pdf]</font size>]] | ||
+ | [[File:Minnesota dominant soil suborders.jpg|thumb|300px|alt=statewide map illustrating karst areas|<font size=3>Statewide map of soil suborders. While soil infiltration rates vary widely within a soil order or suborder, infiltration rates tend to be lower on mollisols, histisols and vertisols compared to entisols, inceptisols, spodosols, and alfisols. Source: [https://extension.umn.edu/soil-management-and-health/soil-orders-and-suborders-minnesota University of Minnesota]</font size>]] | ||
− | + | {{alert|The [http://stormwater.pca.state.mn.us/index.php/Construction_stormwater_permit Construction General Permit] (CGP) prohibits infiltration when an infiltration system will be constructed in areas of predominately Hydrologic Soil Group D (clay) soils.|alert-danger}} | |
− | + | Soils with low infiltration capacity (tight soils) are defined as soils with steady-state infiltration rates equal to or less than 0.06 inches per hour. [https://websoilsurvey.sc.egov.usda.gov/App/HomePage.htm County soil surveys] are useful for initial screening to identify soils that may have low infiltration rates. Most county soil surveys are available digitally from the NRCS (National Resources Conservation Service). These surveys are not accurate enough to determine site-specific characteristics suitable for infiltration systems but are useful for initial screening. If there is a potential for slowly infiltrating soils to exist on a site, a detailed site analysis should be performed for all proposed infiltration BMPs ([[References_for_stormwater_infiltration#S|Susilo, 2009)]]. Additional information on soils can be found [http://stormwater.pca.state.mn.us/index.php/Soils_and_geology here]. | |
− | |||
− | Soils with low infiltration capacity are defined as soils with steady-state infiltration rates equal to or less than 0.06 inches per hour. [ | ||
Stormwater management limitations in areas with tight soils generally preclude large-scale infiltration and ground water recharge (infiltration that passes into the ground water system). These soils will typically be categorized under [[Glossary#H|Hydrologic Soil Group]] (HSG) D. The table below provides a general summary of infiltration rates for different soils. These are conservative estimates of long-term, sustainable infiltration rates that have been documented in Minnesota. They are based on in-situ measurement within existing infiltration practices in Minnesota, rather than national numbers or rates based on laboratory columns. | Stormwater management limitations in areas with tight soils generally preclude large-scale infiltration and ground water recharge (infiltration that passes into the ground water system). These soils will typically be categorized under [[Glossary#H|Hydrologic Soil Group]] (HSG) D. The table below provides a general summary of infiltration rates for different soils. These are conservative estimates of long-term, sustainable infiltration rates that have been documented in Minnesota. They are based on in-situ measurement within existing infiltration practices in Minnesota, rather than national numbers or rates based on laboratory columns. | ||
− | The [http://stormwater.pca.state.mn.us/index.php/Construction_stormwater_permit Construction | + | The [http://stormwater.pca.state.mn.us/index.php/Construction_stormwater_permit Construction General Permit] (CGP) prohibits infiltration when an infiltration system will be constructed in areas of predominately Hydrologic Soil Group D (clay) soils. |
{{:Design infiltration rates}} | {{:Design infiltration rates}} | ||
− | ==Why are soils with a low infiltration capacity a concern== | + | ==Why are soils with a low infiltration capacity a concern?== |
− | Sites with low infiltration capacity soils may limit the type, location, number and/or sizing of infiltration BMPs that can be used for stormwater management. Low infiltration rates result in extended surface ponding of water, which may damage vegetation, lead to mosquito breeding, damage soil structure, and reduce pollutant treatment by the BMP. Certain watershed organizations in Minnesota do not allow the use, or strongly discourage the use, of infiltration BMPs where soil infiltration capacity is low. This does not mean, however, that these soils do not have any infiltration and recharge capabilities. It may be possible for sites to partially or fully meet infiltration objectives as long as appropriate design modifications have been incorporated, such as amending the soil with compost or sand, or incorporating an underdrain into the practice. | + | Sites with low infiltration capacity soils may limit the type, location, number and/or sizing of infiltration BMPs that can be used for stormwater management. Low infiltration rates result in extended surface ponding of water, which may damage vegetation, lead to mosquito breeding, damage soil structure, and reduce pollutant treatment by the BMP. Certain watershed organizations in Minnesota do not allow the use, or strongly discourage the use, of infiltration BMPs where soil infiltration capacity is low. This does not mean, however, that these soils do not have any infiltration and recharge capabilities. It may be possible for sites to partially or fully meet infiltration objectives as long as appropriate design modifications have been incorporated, such as [http://stormwater.pca.state.mn.us/index.php/Turf#Turf_establishment_or_incorporation_in_soil_as_an_amendment amending the soil with compost] or sand, or incorporating an [[Glossary#U|underdrain]] into the practice. |
− | The following table provides an overview of | + | The following table provides an overview of design considerations for several groups of structural practices. |
[[File:Modified sand filter design.png|thumb|300px|alt=schematic of a modified sand filter design|<font size=3>Modified media (sand) filter design</font size>]] | [[File:Modified sand filter design.png|thumb|300px|alt=schematic of a modified sand filter design|<font size=3>Modified media (sand) filter design</font size>]] | ||
Line 24: | Line 24: | ||
{{:BMP use in soil with low infiltration capacity}} | {{:BMP use in soil with low infiltration capacity}} | ||
− | ==How to | + | ==How to investigate soils with low infiltration capacity== |
− | Soil tests to determine infiltration capacity of soil should be performed at all proposed stormwater facilities that plan to have a recharge or infiltration component to their design. The purpose of the testing is to identify and confirm the soil characteristics and determine suitability, if any, for infiltration BMPs. Guidelines for investigating all potential physical constraints to infiltration on a site are presented in | + | Soil tests to determine infiltration capacity of soil should be performed at all proposed stormwater facilities that plan to have a recharge or infiltration component to their design. The purpose of the testing is to identify and confirm the soil characteristics and determine suitability, if any, for infiltration BMPs. Guidelines for investigating all potential physical constraints to infiltration on a site are presented [http://stormwater.pca.state.mn.us/index.php/Procedures_for_investigating_sites_with_potential_constraints_on_stormwater_infiltration in a table at this link]. These guidelines should not be interpreted as all-inclusive. The size and complexity of the project will drive the extent of any subsurface investigation. |
===Subsurface material investigation=== | ===Subsurface material investigation=== | ||
Line 32: | Line 32: | ||
===Location of soil borings=== | ===Location of soil borings=== | ||
Borings should be located in order to provide representative area coverage of the proposed BMP facilities. The location of borings should be: | Borings should be located in order to provide representative area coverage of the proposed BMP facilities. The location of borings should be: | ||
− | * | + | *within each distinct major soil type present, as mapped in [https://websoilsurvey.sc.egov.usda.gov/App/HomePage.htm soil surveys]; |
− | * | + | *near the edges and center of the proposed practice and spaced at equal distances from one another; and |
− | * | + | *near any areas identified as anomalies from any existing geophysical studies. |
===Number of soil borings=== | ===Number of soil borings=== | ||
The number of recommended borings is described below. | The number of recommended borings is described below. | ||
− | *Infiltration trenches, bioretention, and filters - a minimum of 2 per practice. | + | *Infiltration trenches, bioretention, and filters - a minimum of 2 per practice. Note that more borings are recommended for infiltration BMPs greater than 5000 square feet in area. See [http://stormwater.pca.state.mn.us/index.php/Recommended_number_of_soil_boring,_pits,_and_permeameter_tests_for_bioretention_design here] for recommendations on number of borings for infiltration BMPs as a function of BMP size. |
*Ponds/wetlands - a minimum of 3 per practice, or 3 per acre, whichever is greater. | *Ponds/wetlands - a minimum of 3 per practice, or 3 per acre, whichever is greater. | ||
*Additional borings – as needed to define lateral extent of limiting horizons, or site specific conditions, where applicable. | *Additional borings – as needed to define lateral extent of limiting horizons, or site specific conditions, where applicable. | ||
Line 53: | Line 53: | ||
*Log any indications of water saturation to include both perched and ground water table levels, and descriptions of soils that are mottled or gleyed (sticky clay soils typically found in waterlogged soils). | *Log any indications of water saturation to include both perched and ground water table levels, and descriptions of soils that are mottled or gleyed (sticky clay soils typically found in waterlogged soils). | ||
*Measure water levels in all borings at the time of completion and again 24 hours after completion. The boring should remain fully open to total depth of these measurements. | *Measure water levels in all borings at the time of completion and again 24 hours after completion. The boring should remain fully open to total depth of these measurements. | ||
+ | |||
+ | ===References for conducting geotechnical investigations=== | ||
+ | {{alert|A section providing information on soil borings is being developed for the Manual and should be available in early 2016|alert-info}} | ||
+ | |||
+ | The following references provide useful information for conducting geotechnical investigations. Note that some of these documents were written for investigations at contaminated sites. | ||
+ | *[https://www.fhwa.dot.gov/engineering/geotech/pubs/reviewguide/checklist.pdf CHECKLIST AND GUIDELINES FOR REVIEW OF GEOTECHNICAL REPORTS AND PRELIMINARY PLANS AND SPECIFICATIONS] | ||
+ | *[https://www.publications.usace.army.mil/portals/76/publications/engineermanuals/em_1110-1-1804.pdf Geotechnical Investigations] | ||
+ | *[https://dtsc.ca.gov/wp-content/uploads/sites/31/2018/09/Guidelines_for_Planning_and_Implementing_GW_Characterization_of-Contam_Sites.pdf GUIDELINES FOR PLANNING AND IMPLEMENTING GROUNDWATER CHARACTERIZATION OF CONTAMINATED SITES] | ||
+ | *[https://seawi.org/images/downloads/2017_Spring_Conference_Presentations/walters_how_to_read_a_geotech_rpt.pdf How to Read and Understand a Geotechnical Report] | ||
===Infiltration rate testing=== | ===Infiltration rate testing=== | ||
− | Soil permeability should be determined in the field using the | + | Soil permeability should be determined in the field using the [https://stormwater.pca.state.mn.us/index.php?title=Determining_soil_infiltration_rates#Soil_property_determination_for_infiltration_SCM_design procedures described here]. |
+ | <!-- | ||
*Install casing (solid 6-inch diameter) to 36 inches below proposed BMP bottom. | *Install casing (solid 6-inch diameter) to 36 inches below proposed BMP bottom. | ||
*Remove any smeared soiled surfaces and provide a natural soil interface into which water may percolate. Remove all loose material from the casing. Upon the tester’s discretion, a 2 inch layer of coarse sand or fine gravel may be placed to protect the bottom from scouring. Fill casing with clean water to a depth of 36 inches and allow to pre-soak for up to 24 hours. | *Remove any smeared soiled surfaces and provide a natural soil interface into which water may percolate. Remove all loose material from the casing. Upon the tester’s discretion, a 2 inch layer of coarse sand or fine gravel may be placed to protect the bottom from scouring. Fill casing with clean water to a depth of 36 inches and allow to pre-soak for up to 24 hours. | ||
Line 61: | Line 71: | ||
*May be done through a boring or open excavation that is protected from access by the public. | *May be done through a boring or open excavation that is protected from access by the public. | ||
*The location of the test should correspond to the BMP location. | *The location of the test should correspond to the BMP location. | ||
− | Upon completion of the testing, the casings should be immediately pulled, and the test pit should be back-filled. | + | Upon completion of the testing, the casings should be immediately pulled, and the test pit should be back-filled.--> |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | ==What are general stormwater management guidelines for sites with low infiltration capacity soils?== | |
− | + | *Local soil surveys should be used for preliminary determination of infiltration capacity of the soils on site; if the soil survey suggests soils with very low infiltration capacities, then alternative BMPs such as filters, wet sedimentation basins, etc. should be considered. If the survey suggests the potential for infiltration, the on-site soil testing should be done to accurately characterize site soils. The testing should be conducted in the most restrictive layer of soil that is found within 5-feet below the bottom of the proposed BMP. | |
− | + | *[http://stormwater.pca.state.mn.us/index.php/Turf#Turf_establishment_or_incorporation_in_soil_as_an_amendment Soil compost amendments] should be considered for lawns and other pervious surfaces to increase pervious area storage and/or decrease pervious surface runoff. Designers should also consider disconnection of impervious surfaces, by draining rooftops and other impervious surface runoff to compost amended pervious surfaces before collection and discharge into a structural BMP. | |
− | + | *Where volume reduction is a primary objective for a site (e.g., required by permit, potentially a receiving water-based goal due to channel erosion, nuisance flooding, or inadequate infrastructure capacity), emphasis should be placed on practices that promote [http://stormwater.pca.state.mn.us/index.php/Stormwater_re-use_and_rainwater_harvesting runoff reuse] and evapotranspiration such as cisterns, rain barrels, [[Green roofs|green roofs]], and [[Bioretention|biofiltration]] in order to maximize volume reduction. | |
− | + | *A [http://stormwater.pca.state.mn.us/index.php/Stormwater_infiltration_and_groundwater_mounding mounding analysis] should be conducted to ensure that any groundwater mound that develops under a BMP will not extend into the BMP. This mounding analysis is especially important for soils with low permeability since such soils cannot efficiently dissipate groundwater through the soil column. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | *Local soil surveys should be used for preliminary determination of infiltration capacity of site soils | ||
− | |||
− | * | ||
− | *Where volume reduction is a primary objective for a site (e.g., potentially a receiving water-based goal due to channel erosion, nuisance flooding, or inadequate infrastructure capacity), emphasis should be placed on practices that promote | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | * | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==Related pages== | ==Related pages== | ||
− | *[[Overview of stormwater infiltration | + | *[[Overview of stormwater infiltration]] |
*[[Pre-treatment considerations for stormwater infiltration]] | *[[Pre-treatment considerations for stormwater infiltration]] | ||
− | *[[BMPs for stormwater infiltration | + | *[[BMPs for stormwater infiltration]] |
*[[Pollutant fate and transport in stormwater infiltration systems]] | *[[Pollutant fate and transport in stormwater infiltration systems]] | ||
*[[Surface water and groundwater quality impacts from stormwater infiltration]] | *[[Surface water and groundwater quality impacts from stormwater infiltration]] | ||
− | *[[Stormwater infiltration and groundwater | + | *[[Stormwater infiltration and groundwater mounding]] |
− | *[[Stormwater infiltration and setback (separation) | + | *[[Stormwater infiltration and setback (separation) distances]] |
*[[Karst]] | *[[Karst]] | ||
*[[Shallow soils and shallow depth to bedrock]] | *[[Shallow soils and shallow depth to bedrock]] | ||
*[[Shallow groundwater]] | *[[Shallow groundwater]] | ||
+ | *[[Soils with low infiltration capacity]] | ||
*[[Potential stormwater hotspots]] | *[[Potential stormwater hotspots]] | ||
− | *[[Stormwater and wellhead | + | *[[Stormwater and wellhead protection]] |
− | *[[Stormwater | + | *[[Stormwater infiltration and contaminated soils and groundwater]] |
− | *[[Decision tools for stormwater infiltration | + | *[[Decision tools for stormwater infiltration]] |
− | |||
*[[References for stormwater infiltration]] | *[[References for stormwater infiltration]] | ||
<noinclude> | <noinclude> | ||
− | [[Category: | + | [[Category:Level 2 - Technical and specific topic information/infiltration]] |
+ | [[Category:Level 2 - Technical and specific topic information/soils and media]] | ||
</noinclude> | </noinclude> |
Soils with low infiltration capacity (tight soils) are defined as soils with steady-state infiltration rates equal to or less than 0.06 inches per hour. County soil surveys are useful for initial screening to identify soils that may have low infiltration rates. Most county soil surveys are available digitally from the NRCS (National Resources Conservation Service). These surveys are not accurate enough to determine site-specific characteristics suitable for infiltration systems but are useful for initial screening. If there is a potential for slowly infiltrating soils to exist on a site, a detailed site analysis should be performed for all proposed infiltration BMPs (Susilo, 2009). Additional information on soils can be found here.
Stormwater management limitations in areas with tight soils generally preclude large-scale infiltration and ground water recharge (infiltration that passes into the ground water system). These soils will typically be categorized under Hydrologic Soil Group (HSG) D. The table below provides a general summary of infiltration rates for different soils. These are conservative estimates of long-term, sustainable infiltration rates that have been documented in Minnesota. They are based on in-situ measurement within existing infiltration practices in Minnesota, rather than national numbers or rates based on laboratory columns.
The Construction General Permit (CGP) prohibits infiltration when an infiltration system will be constructed in areas of predominately Hydrologic Soil Group D (clay) soils.
Design infiltration rates, in inches per hour, for A, B, C, and D soil groups. Corresponding USDA soil classification and Unified soil Classifications are included. Note that A and B soils have two infiltration rates that are a function of soil texture.*
The values shown in this table are for uncompacted soils. This table can be used as a guide to determine if a soil is compacted. For information on alleviating compacted soils, link here. If a soil is compacted, reduce the soil infiltration rate by one level (e.g. for a compacted B(SM) use the infiltration rate for a B(MH) soil).
Link to this table
Hydrologic soil group | Infiltration rate (inches/hour) | Infiltration rate (centimeters/hour) | Soil textures | Corresponding Unified Soil ClassificationSuperscript text |
---|---|---|---|---|
Although a value of 1.63 inches per hour (4.14 centimeters per hour) may be used, it is Highly recommended that you conduct field infiltration tests or amend soils.b See Guidance for amending soils with rapid or high infiltration rates and Determining soil infiltration rates. |
gravel |
GW - Well-graded gravels, fine to coarse gravel GP - Poorly graded gravel |
||
1.63a | 4.14 |
silty gravels |
GM - Silty gravel |
|
0.8 | 2.03 |
sand |
SP - Poorly graded sand |
|
0.45 | 1.14 | silty sands | SM - Silty sand | |
0.3 | 0.76 | loam, silt loam | MH - Elastic silt | |
0.2 | 0.51 | Sandy clay loam, silts | ML - Silt | |
0.06 | 0.15 |
clay loam |
GC - Clayey gravel |
1For Unified Soil Classification, we show the basic text for each soil type. For more detailed descriptions, see the following links: The Unified Soil Classification System, CALIFORNIA DEPARTMENT OF TRANSPORTATION (CALTRANS) UNIFIED SOIL CLASSIFICATION SYSTEM
Source: Thirty guidance manuals and many other stormwater references were reviewed to compile recommended infiltration rates. All of these sources use the following studies as the basis for their recommended infiltration rates: (1) Rawls, Brakensiek and Saxton (1982); (2) Rawls, Gimenez and Grossman (1998); (3) Bouwer and Rice (1984); and (4) Urban Hydrology for Small Watersheds (NRCS). SWWD, 2005, provides field documented data that supports the proposed infiltration rates. (view reference list)
aThis rate is consistent with the infiltration rate provided for the lower end of the Hydrologic Soil Group A soils in the Stormwater post-construction technical standards, Wisconsin Department of Natural Resources Conservation Practice Standards.
bThe infiltration rates in this table are recommended values for sizing stormwater practices based on information collected from soil borings or pits. A group of technical experts developed the table for the original Minnesota Stormwater Manual in 2005. Additional technical review resulted in an update to the table in 2011. Over the past 5 to 7 years, several government agencies revised or developed guidance for designing infiltration practices. Several states now require or strongly recommend field infiltration tests. Examples include North Carolina, New York, Georgia, and the City of Philadelphia. The states of Washington and Maine strongly recommend field testing for infiltration rates, but both states allow grain size analyses in the determination of infiltration rates. The Minnesota Stormwater Manual strongly recommends field testing for infiltration rate, but allows information from soil borings or pits to be used in determining infiltration rate. A literature review suggests the values in the design infiltration rate table are not appropriate for soils with very high infiltration rates. This includes gravels, sandy gravels, and uniformly graded sands. Infiltration rates for these geologic materials are higher than indicated in the table.
References: Clapp, R. B., and George M. Hornberger. 1978. Empirical equations for some soil hydraulic properties. Water Resources Research. 14:4:601–604; Moynihan, K., and Vasconcelos, J. 2014. SWMM Modeling of a Rural Watershed in the Lower Coastal Plains of the United States. Journal of Water Management Modeling. C372; Rawls, W.J., D. Gimenez, and R. Grossman. 1998. Use of soil texture, bulk density and slope of the water retention curve to predict saturated hydraulic conductivity Transactions of the ASAE. VOL. 41(4): 983-988; Saxton, K.E., and W. J. Rawls. 2005. Soil Water Characteristic Estimates by Texture and Organic Matter for Hydrologic Solutions. Soil Science Society of America Journal. 70:5:1569-1578.
Sites with low infiltration capacity soils may limit the type, location, number and/or sizing of infiltration BMPs that can be used for stormwater management. Low infiltration rates result in extended surface ponding of water, which may damage vegetation, lead to mosquito breeding, damage soil structure, and reduce pollutant treatment by the BMP. Certain watershed organizations in Minnesota do not allow the use, or strongly discourage the use, of infiltration BMPs where soil infiltration capacity is low. This does not mean, however, that these soils do not have any infiltration and recharge capabilities. It may be possible for sites to partially or fully meet infiltration objectives as long as appropriate design modifications have been incorporated, such as amending the soil with compost or sand, or incorporating an underdrain into the practice.
The following table provides an overview of design considerations for several groups of structural practices.
This table shows structural BMP use in soil with low infiltration capacity
Link to this table
BMP | Low infiltration capacity soil considerations |
---|---|
Bioretention, dry swale, permeable pavement, tree trench/box | Should be constructed with an underdrain. Recharge criteria, if applicable, can be met by modifying the design to include an infiltration gallery below the underdrain, so long as it is appropriately sized. |
Media filter | Recommended practice in tight soils. Some design variants can be modified to incorporate an infiltration gallery that can help meet recharge criteria, if properly sized. |
Infiltration trench or basin |
|
Stormwater ponds | Acceptable practice with tight soils. Soils should help maintain permanent pool. |
Constructed wetlands |
|
Soil tests to determine infiltration capacity of soil should be performed at all proposed stormwater facilities that plan to have a recharge or infiltration component to their design. The purpose of the testing is to identify and confirm the soil characteristics and determine suitability, if any, for infiltration BMPs. Guidelines for investigating all potential physical constraints to infiltration on a site are presented in a table at this link. These guidelines should not be interpreted as all-inclusive. The size and complexity of the project will drive the extent of any subsurface investigation.
Soil testing is recommended for all proposed stormwater facilities that plan to have a recharge or infiltration component to their design. Testing can be less rigorous than that for karst areas or sites with shallow bedrock and groundwater. The investigation is designed to identify and confirm the soil characteristics and determine their suitability, if any, for infiltration practices.
Borings should be located in order to provide representative area coverage of the proposed BMP facilities. The location of borings should be:
The number of recommended borings is described below.
Borings should be extended to a minimum depth of 5 feet below the lowest proposed grade within the practice unless auger/backhoe refusal is encountered.
All material penetrated by the boring should be identified, as follows:
The following references provide useful information for conducting geotechnical investigations. Note that some of these documents were written for investigations at contaminated sites.
Soil permeability should be determined in the field using the procedures described here.
This page was last edited on 15 February 2023, at 13:24.