Pretreatment reduces maintenance and prolongs the lifespan of structural stormwater BMPs by removing trash, debris, organic materials, coarse sediments, and associated pollutants prior to entering structural stormwater BMPs. Implementing pretreatment devices also improves aesthetics by capturing debris in focused or hidden areas. | Pretreatment reduces maintenance and prolongs the lifespan of structural stormwater BMPs by removing trash, debris, organic materials, coarse sediments, and associated pollutants prior to entering structural stormwater BMPs. Implementing pretreatment devices also improves aesthetics by capturing debris in focused or hidden areas. | ||
Line 121: | Line 123: | ||
*[[Photo gallery for pretreatment]] | *[[Photo gallery for pretreatment]] | ||
− | [[Category:Pretreatment]] | + | [[Category:Level 2 - Best management practices/Pretreatment practices]] |
</noinclude> | </noinclude> |
Pretreatment reduces maintenance and prolongs the lifespan of structural stormwater BMPs by removing trash, debris, organic materials, coarse sediments, and associated pollutants prior to entering structural stormwater BMPs. Implementing pretreatment devices also improves aesthetics by capturing debris in focused or hidden areas.
To perform efficiently, pretreatment practices must be properly sized. Given the lack of a consistent approach in stormwater pretreatment sizing in the literature, we developed a sizing approach focused on removing a specific fraction of sediment. This approach is dependent on the settling velocity of different sized particles.
This page provides an approach to pretreatment sizing. For the technical development of this methodology, link here.
Basins are stormwater best management practices (BMPs) having an engineered pool that promotes settling of solids (e.g., pond forebay, sump, hydrodynamic separator, and catch basin). These pretreatment facilities are typically small (relative to the primary treatment practice) but can be sized to settle gravel and sands, and possibly silts, at low flow conditions. For preliminary sizing purposes, the small size results in a basin that is close to well-mixed, where the concentration of suspended solids is constant with depth to the bottom of the basin and the particles are settling out because of zero velocity at the wall.
Calculate the area of the pretreatment basin from AS = (FR * I * A * FR) / (vS * (1 - FR))
For the following calculation, ensure your units are consistent
Settling velocity according to Equation 8 of various equivalent spherical diameter sand and silt particles at 20°C. | ||
Silt and sand Diameter (um) | vs (m/s) | Header text (ft/s) |
---|---|---|
10 | 0.000089 | 0.00029 |
30 | 0.00078 | 0.0026 |
80 | 0.0051 | 0.017 |
100 | 0.0075 | 0.025 |
150 | 0.015 | 0.049 |
200 | 0.023 | 0.075 |
500 | 0.071 | 0.23 |
1000 | 0.13 | 0.43 |
One of the inlets into a 2-acre pond is draining a directly connected impervious area of 30 acres. The pretreatment basin for the 2-acre pond will be designed to retain 70 percent of the 80 μm fine-sand particles. Using adjacent table, the settling velocity (vS) for 80 μm fine-sand particles is 0.017 feet per second (fps). For this case, the values to be input into the calculation are
Plugging the these into the equation AS = (FR * I * A * FR) / (vS * (1 - FR)) yields a value of 1453 ft2 for the area of the forebay. The depth is the lesser of 6 feet or the square root of the forebay area (square root of 1453 = 38.1). The depth is therefore 6 feet.
Filter strips are primarily designed to enhance settling; physical filtering of particles in a filter strip is minimal. The filter strip is located at the bottom of a shallow, widely spread, open channel flow to allow for particle settling through the media, which is often grass or rocks. The grass or rocks allow space for the settled particles to collect until cleanout is required.
LW = - ((c * I * A) / (vS) * ln(1 - FR)) where c = 0.7 for small storms
For the following calculation, ensure your units are consistent
A directly connected impervious area of 10,000 ft2 drains into a bioretention practice. The area is a sufficient size to install a well-sized filter strip, so the designer chose to settle 80 percent of the 80 um fine-sand particles in the filter strip during the design storm. For this case, the values to be used are
Plugging these values into the equation LW = - ((0.7 * 10000 ft2) * 0.5 in/hr) / 0.017 ft/s) * ln(1-0.8) = 7.6 ft2
Assuming a 3-ft wide inlet, the filter strip would need to be a minimum of 2.5 ft (L = LW/W = 7.6 ft2/3 ft = 2.5 ft) in length by 2.5-ft. To settle 80 percent of the fine sand particles entering this bioretention practice, the filter strip is recommended to be 3 ft wide by 2.5 ft long.