| MIDS Stormwater Pond Design Level1 | Permanent Pool Volume (Vpp), ft3 | Water Quality Volume (Vwq), ft3 | Pollutant reduction (%)2 | |||
|---|---|---|---|---|---|---|
| TSS | TP | PP | DP | |||
| Design Level 1 | ≥ 1,800 ft3 per acre of tributary area | <= 1 inch from impervious area | 60 | 34 | 62 | 0 |
| Design Level 2 | <= 1 inch from impervious area | 84 | 50 | 84 | 8 | |
| Design Level 3 | <= 1.5 inch from impervious area | 90 | 60 | 90 | 23 | |
| 1From MIDS Calculator documentation for stormwater ponds. Note: the table summarizes design-level criteria related to permanent pool volume and water quality volume. The complete list of criteria for each design level is summarized on the MIDS calculator website linked above. 2 TSS = total suspended solids; TP = total phosphorus; PP = particulate phosphorus; and DP = dissolved phosphorus. Pollutant reduction values cited assume no upstream treatment within tributary area to pond (i.e., untreated urban runoff). |
||||||