| Stormwater BMP | Illustration | Pollutant Removal Mechanism | Location in Treatment Train | Pollutant Removal 1,2 | Potential Application 1 |
|---|---|---|---|---|---|
| Infiltration Basin | Sedimentation / Infiltration | End |
TSS: High TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High Pathogens: High |
Residential: Yes Commercial: Yes Ultra Urban: Limited Industrial: Limited Retrofit: Yes Highway/Road: Limited |
|
| Bioinfiltration Basin | Sedimentation / Infiltration | Beginning |
TSS: High TN: Low/Medium TP: Medium/High Chloride: Low Metals: High Oils and Grease: High |
Residential: Yes Commercial: Yes Ultra Urban: Limited Industrial: Limited Retrofit: Yes Highway/Road: Limited |
|
| Infiltration Trench Synonym: Infiltration Gallery |
Infiltration | nd |
TSS: High TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High Pathogens: High |
Residential: Yes Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes Highway/Road: Yes |
|
| Dry Well Synonym: Infiltration Tube, French Drain, Soak‐Away Pits, Soak Holes |
Infiltration | throughout |
TSS: High TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High Pathogens: High |
Residential: Yes Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes Highway/Road: No |
|
| Underground Infiltration | Sedimentation / Infiltration / Flotation/Skimming | End |
TSS: High TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High Pathogens: High |
Residential: Yes Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes Highway/Road: Limited |
|
| Dry Swale with Check Dams | Sedimentation / Infiltration | Throughout |
TSS: High TN: Low/Medium TP: Low/Medium Chloride: Low Metals: High Oils and Grease: High Pathogens: Medium |
Residential: Yes Commercial: Yes Ultra Urban: Limited Industrial: Yes Retrofit: Limited Highway/Road: Yes |
|
| Permeable Pavement | Infiltration | Beginning |
TSS: High TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High |
Residential: Yes Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes Highway/Road: Limited |
|
| Tree Trench/Tree Box | Infiltration, Transpiration | Throughout |
TSS: High TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High Pathogens: High |
Residential: Limited Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes Highway/Road: Limited |
|
| 1 Treatment Capabilities and Potential Applications referenced from Manual Section BMP's for stormwater infiltration 2 Low = < 30%; Medium = 30‐65%; High = 65‐100% |
|||||